A Bangladesh AC tonnage calculator is not the same animal as the one you find on a US air-conditioning site. Dhaka summers hit 35°C ambient with 80% humidity. Walls hold heat well past sunset. Most flats face direct west sun on at least one side. So the BTU per square foot figure you need is higher than what global calculators suggest. The honest sizing rule for a Bangladeshi room is roughly 100 BTU per square foot of floor area once you bake in the sun, the humidity and the brick-wall heat radiation that every Dhaka flat deals with. That figure gets you to the right ton in one quick calculation. Below is the calculator, the room-to-ton chart, the matching Pickaboo picks at every tonnage tier and the local factors most buyers miss.
Quick answer for the most common Bangladeshi rooms:
| Room | Floor area | Recommended AC ton |
|---|---|---|
| Single bedroom, no west sun | Up to 100 sq ft | 0.75 ton (9,000 BTU) |
| Standard bedroom | 100 to 140 sq ft | 1 ton (12,000 BTU) |
| Master bedroom | 140 to 180 sq ft | 1.5 ton (18,000 BTU) |
| Drawing room or large master | 180 to 240 sq ft | 2 ton (24,000 BTU) |
| Hall, shop, large drawing | 240 to 350 sq ft | 2.5 ton (30,000 BTU) |
Want the working? Keep reading. Already know your room and just want a model? Jump to the picks per tonnage tier.
How to Size an AC for a Bangladeshi Room
Three steps. Two of them you do with a measuring tape. The last one is a single line of arithmetic.
Step 1: Measure the room
Length × width in feet. A 12 ft by 14 ft bedroom is 168 sq ft. If the room is L-shaped, treat it as two rectangles and add the totals. Skip the bathroom and the balcony.
Step 2: Apply the Bangladesh load factor
Multiply the square feet by 100 BTU. That gives you the practical cooling load for a Dhaka flat.
Required BTU = Floor area (sq ft) × 100
Why 100 and not the 20 to 25 quoted on most US calculators? Three reasons that apply only to Bangladesh:
- Daytime ambient sits at 32 to 36°C from April through September. Higher on west-facing rooms in the afternoon.
- Outdoor humidity stays above 70% for most of the AC season. Your unit is not just cooling air; it is also pulling moisture out of it.
- Most Bangladeshi flats are red-brick and concrete with no real wall insulation. Heat soaks into the walls all day and radiates back into the room until 11pm.
Stack those three together and you get something close to 100 BTU per sq ft as the working figure that local installers actually size to.
Step 3: Convert BTU to tons
Divide the required BTU by 12,000.
Ton = Required BTU ÷ 12,000
Round up to the next standard tonnage. ACs in Bangladesh sell in 0.75, 1, 1.5, 2 and 2.5 ton sizes. If your figure lands at 1.7 ton, you buy a 2 ton, not a 1.5 ton. No exceptions.
Worked example: a 12 ft by 14 ft bedroom in Mirpur
Area: 12 × 14 = 168 sq ft. Required BTU: 168 × 100 = 16,800. Tons: 16,800 ÷ 12,000 = 1.4. Round up. Buy a 1.5 ton.
If the same room sits on the top floor or has a west-facing window that catches the 4pm sun, push it to a 2 ton. The chart below shows when to step up.
Room Size to AC Ton Chart for Bangladesh
The full chart so you do not have to do the maths. All values assume a typical Dhaka or Chittagong flat with painted walls, average curtains, ceiling height of 8 to 9 ft and two occupants in the room.
| Room area (sq ft) | Required BTU | Standard AC ton | Pickaboo collection |
|---|---|---|---|
| Up to 80 sq ft | 8,000 BTU | 0.75 ton | 0.75 ton AC |
| 80 to 120 sq ft | 9,000 to 12,000 BTU | 1 ton | 1 ton AC |
| 120 to 180 sq ft | 13,000 to 18,000 BTU | 1.5 ton | 1.5 ton AC |
| 180 to 240 sq ft | 19,000 to 24,000 BTU | 2 ton | 2 ton AC |
| 240 to 320 sq ft | 25,000 to 30,000 BTU | 2.5 ton | 2.5 ton AC |
| 320 to 500 sq ft | 32,000 to 48,000 BTU | 3 to 4 ton split or VRF | Air conditioner |
| 500+ sq ft | 50,000+ BTU | Multi-split or cassette | Office AC planner |
Shops, showrooms and offices have a different load profile. Use the office tonnage planner for those.
The Bangladesh Adjustments That Change Your Answer
Run through this checklist before you commit. If two or more apply, go up by one tonnage tier.
West sun all afternoon
A 130 sq ft bedroom with a 4 by 6 ft west-facing window absorbs about as much heat at 4pm as a 160 sq ft north-facing room. Most Mirpur, Mohammadpur and Bashundhara flats sit on east-west alignment, so this catches a lot of buyers off guard.
Top-floor flat in a 6-storey building
The roof slab radiates heat downward all evening. If you are on the top floor of an uninsulated walk-up, your ceiling temperature at 8pm sits 3 to 5°C above the floor below. Add 10% to your BTU figure.
Open-plan kitchen, or kitchen wall shared with the AC room
Cooking heat leaks through. A 130 sq ft drawing room that shares a wall with an active kitchen behaves like a 170 sq ft room from the AC’s point of view.
Tin-shed or semi-pucca structure
Mango orchards in Rajshahi, semi-pucca homes in coastal districts, factory dormitories and hostel rooms with tin roofs. The load multiplier here climbs to roughly 130 BTU per sq ft. Step up by one full tier and pick a model rated for high ambient (52°C T3 rating).
More than three people, often
A bedroom that doubles as an exam-time study cubicle for three teenagers and a tutor needs 1.5 ton even at 110 sq ft. Each adult body adds about 600 BTU of heat. Sounds small. Adds up quickly.
Glass walls or balcony doors
Sliding glass doors in modern Gulshan and Banani flats look beautiful and they leak heat. A 160 sq ft glass-walled room behaves like 220 sq ft. Buy 2 ton, not 1.5 ton.
What Ton AC for My Room: The Quick Decisions
For people who do not want to read the full guide, the answer for the most common Bangladeshi setups:
| Setup | Buy this |
|---|---|
| Standard bedroom in a Dhaka flat (10 by 12 to 12 by 14 ft) | 1 ton inverter |
| Master bedroom (12 by 14 ft up to 13 by 16 ft) | 1.5 ton inverter |
| Drawing room of a 1,200 sq ft flat | 2 ton inverter |
| Drawing-cum-dining of a 1,500 sq ft flat | 2.5 ton inverter or 1 + 1.5 ton split |
| Single-bachelor sublet, 90 sq ft | 0.75 ton (or 1 ton if the budget stretches) |
| Top-floor master bedroom with west sun | One tier above the chart |
| Office cabin, 100 to 140 sq ft, 1 to 2 PCs | 1 ton |
| Office floor, 400 sq ft, 8 to 10 desks | 2 × 2 ton or 1 × 4 ton cassette |
| Shop, 200 sq ft with glass front | 2 ton, T3 rated |
Picks per Tonnage Tier on Pickaboo
Now that you know the right ton, here are the verified models on Pickaboo at each tier. All prices are live as of April 2026 and qualify for 0% EMI. Walton models and selected Ramadan-offer bundles come with free installation. Everything else is fitted for an extra Tk 3,000 to Tk 5,000.
0.75 ton (rooms up to 80 sq ft)
The 0.75 ton tier is thin in Bangladesh. Most brands skip 9,000 BTU and start their lineup at 12,000 BTU. If you have a single-bachelor sublet in Dhanmondi or a 7 by 10 ft hostel cabin, the realistic move is to step up to 1 ton and let the thermostat short-cycle the unit. The closest small option in stock is the Walton 1 Ton Riverine Inverter AC (WSI-RIVERINE PRIME-12J).
1 ton (rooms 80 to 120 sq ft)
The default for a standard single bedroom, a hostel double or a small home office.
| Model | Price (Tk) | Type | Best for |
|---|---|---|---|
| Walton 1 Ton Riverine Inverter AC (WSI-RIVERINE PRIME-12J) | From 42,990 | Inverter | District towns, longest service network |
| Walton 1 Ton Inverter AC (WSI-INVERNA SUPERSAVER-12F PLASMA) | From 43,990 | Inverter, plasma filter | Humid bedrooms, allergy sufferers |
| Walton 1 Ton Intelligent Inverter (WSI-OCEANUS-12J) | From 47,500 | Inverter, premium local | Long-cycle bedrooms, 10+ hr daily use |
| Hisense 1 Ton Inverter AC (AS-12TW4RYETD00BU) | From 48,990 | Full DC inverter | Master bedroom in divisional cities |
| Midea 1 Ton Inverter AC (MSI12CRN) | From 45,990 | Inverter, R32 | Budget-conscious Dhaka buyers |
| Gree 1 Ton Inverter Split AC (GS12XPUV32) | From 56,990 | Inverter, premium import | Brand-trust priority |
Editor’s pick at 1 ton: the Midea 1 Ton Inverter (MSI12CRN) for budget buyers in Dhaka and the Walton 1 Ton Riverine Inverter for buyers outside divisional cities. The price gap pays itself back in service-call convenience over the AC’s lifetime.
1.5 ton (rooms 120 to 180 sq ft)
The single biggest selling tier in Bangladesh. The master-bedroom default.
| Model | Price (Tk) | Type | Best for |
|---|---|---|---|
| Haier 1.5 Ton TurboCool Non-Inverter AC | From 46,990 | Non-inverter | Tight budgets, occasional use |
| Midea 1.5 Ton Inverter AC (MSI18CRN) | From 48,990 | Inverter, R32 | Best value 1.5 ton inverter on Pickaboo |
| Haier 1.5 Ton CleanCool Inverter AC | From 50,990 | DC inverter | Self-clean, low maintenance |
| Hisense 1.5 Ton Full DC Inverter | From 56,990 | Full DC inverter | Long daily run hours |
| Walton 1.5 Ton Intelligent Inverter (SUPERSAVER-18H PLASMA) | From 60,990 | Inverter, plasma filter | District-town buyers, long warranty |
| Gree 1.5 Ton Inverter Split AC (GS18XPUV32) | From 62,990 | Inverter | Brand trust, divisional service |
| Haier 1.5 Ton ZenGlow Inverter | From 64,990 | DC inverter, premium | Bill-conscious buyers |
For the full breakdown including monthly running cost, see the 1.5 ton AC price guide.
Editor’s pick at 1.5 ton: the Midea 1.5 Ton Inverter (MSI18CRN) if you want to stay under Tk 50,000 and the Walton SUPERSAVER-18H PLASMA if you live outside Dhaka and value the longest after-sales reach in the country.
2 ton (rooms 180 to 240 sq ft)
Drawing rooms, large master bedrooms, small open-plan offices.
| Model | Price (Tk) | Type | Best for |
|---|---|---|---|
| Midea 2 Ton Inverter AC (MSI24CRN) | From 75,990 | Inverter | Best-value 2 ton inverter |
The 2 ton tier on Pickaboo is led by the Midea MSI24CRN at the entry price point. Walton, Gree and Haier 2 ton inverter models sit between Tk 85,000 and Tk 1,15,000 depending on inverter rating. The full 2 ton list with monthly bill calculations sits in the best 2 ton AC in Bangladesh guide.
2.5 ton (rooms 240 to 320 sq ft)
Halls, shops, large drawing-cum-dining halls. Buyers at this tonnage are often shop owners and showroom operators. The office AC planner covers commercial sizing in detail.
For most home halls of 250 sq ft or more, two 1.5 ton splits work better than one 2.5 ton. The maths:
- One 2.5 ton runs 30,000 BTU. If half the hall is empty at any moment, you pay to cool air nobody is sitting in.
- Two 1.5 ton splits give you zoning. Run one for the dining side at lunch, one for the drawing side in the evening.
The two-unit setup also beats single 2.5 ton on resilience. If one fails on a Friday afternoon, the other carries the room while you wait for a technician.
Why Oversizing and Undersizing Both Cost You Money
A common myth in Bangladesh: “buy bigger, it cools faster.” Wrong on three counts.
Oversized AC
A 2 ton AC in a 100 sq ft bedroom hits the set temperature in 5 minutes, switches off, switches back on 4 minutes later, then off again. That short-cycling does three things you do not want:
- The compressor wears out faster than the warranty implies. The 12-year cover protects the part. It does not stop the service-call frequency from climbing.
- The unit never runs long enough to dehumidify the room properly. You end up with a cold room that still feels clammy.
- Your electricity bill is 25 to 30% higher than a correctly sized unit, since compressor start-up draws the highest current.
Undersized AC
A 1 ton AC in a 200 sq ft drawing room never reaches your set temperature. The compressor runs continuously. The room sits at 26 to 28°C even when you set 22. The bill stacks up since the unit never cycles off.
The right size, with maybe a 10% margin for hot afternoons, is what gives you the lowest 5-year total cost of ownership. Plain and simple.
Room-by-room Sizing for Typical Bangladeshi Flats
1,000 sq ft 2-bedroom flat in Dhanmondi
| Room | Area | AC needed |
|---|---|---|
| Master bedroom | 150 sq ft | 1.5 ton |
| Second bedroom | 110 sq ft | 1 ton |
| Drawing | 220 sq ft | 2 ton (or skip and run a ceiling fan with an air cooler) |
| Total tonnage | 4.5 ton if you cool every room |
1,400 sq ft 3-bedroom flat in Bashundhara
| Room | Area | AC needed |
|---|---|---|
| Master bedroom | 170 sq ft | 1.5 ton |
| Second bedroom | 130 sq ft | 1 ton |
| Third bedroom (kids) | 110 sq ft | 1 ton |
| Drawing | 240 sq ft | 2 ton |
| Total tonnage | 5.5 ton |
600 sq ft single-room sublet in Mirpur
| Area | AC needed |
|---|---|
| 110 sq ft sleeping zone | 1 ton inverter |
220 sq ft retail shop in New Market
| Area | Footfall | AC needed |
|---|---|---|
| 220 sq ft | High, glass front | 2 ton T3-rated, plus exhaust fan |
The T3 rating matters for shops since the outdoor unit on a New Market or Bangabazar shopfront often sits in a chase that hits 50°C in May.
What Changes Outside Dhaka
Chittagong and the coastal cities
Salt-laden air rusts unprotected outdoor coils within 18 months. Look for “anti-corrosion blue fins” or “gold fin” coatings on the outdoor unit spec sheet. Walton, Gree and Haier all sell anti-corrosion variants in Chittagong. Worth the extra Tk 3,000 over the standard model if you live within 5 km of the coast.
Sylhet and high-rainfall districts
Long monsoon, high humidity, less peak heat. A 1.5 ton inverter handles a 180 sq ft bedroom comfortably even when a Dhaka room of the same size pushes the same unit. The chart still applies. You will simply use less of the available capacity day to day.
Rajshahi, Khulna and the northern dry zone
Lower humidity, higher dry-bulb temperature. Cooling load is similar to Dhaka but dehumidification matters less. Non-inverter ACs perform almost as well as inverters here. If your budget is tight, a 1.5 ton non-inverter is a defensible choice in Rajshahi where it is not in Dhaka. Honest sales advice nobody gives you in the showroom.
District towns with weak grid voltage
Voltage in many district towns drops to 180 V during evening peak. Inverter ACs handle that better than non-inverters but you still want a stabiliser rated for 180 to 260 V input. Add Tk 3,500 to Tk 5,000 to your budget for a stabiliser if you live outside the divisional capital. The AC installation cost guide covers stabiliser pricing.
Top-floor flats in 6-storey walk-ups
Add 10% to whatever the chart says. The roof radiates heat downward through the night and your AC has to fight it.
Cost of Running each Tonnage at Dhaka Tariffs
Dhaka residential tariff in 2026 is roughly Tk 7.20 per unit (kWh) in the 200 to 400 unit slab. At 8 hours of daily use across the April-to-September AC season:
| AC tonnage | Avg draw (inverter) | Daily units (8 hr) | Monthly bill |
|---|---|---|---|
| 0.75 ton | 0.65 kW | 5.2 kWh | Tk 1,123/month |
| 1 ton | 0.85 kW | 6.8 kWh | Tk 1,469/month |
| 1.5 ton | 1.20 kW | 9.6 kWh | Tk 2,074/month |
| 2 ton | 1.55 kW | 12.4 kWh | Tk 2,679/month |
| 2.5 ton | 1.95 kW | 15.6 kWh | Tk 3,370/month |
Non-inverter equivalents draw 30 to 50% more, so add that on top. Buying the right tonnage matters more for the monthly bill than buying a “premium” model at the wrong size. Right size first, brand second. That is the order most Pickaboo customers wish they had followed.
Buy AC by Tonnage on Pickaboo
- 1 ton AC collection on Pickaboo
- 1.5 ton AC collection on Pickaboo
- 2 ton AC collection on Pickaboo
- Browse all air conditioners
Every AC on Pickaboo qualifies for 0% EMI through bank partners and selected Walton, Gree and Ramadan-offer models come bundled with free installation.
Frequently Asked Questions
What ton AC for my room of 12 by 14 ft?
A 12 by 14 ft room is 168 sq ft. Multiply by 100 BTU per sq ft (the practical Bangladesh load factor). That gives 16,800 BTU, which sits between 1 ton (12,000 BTU) and 1.5 ton (18,000 BTU). Buy a 1.5 ton inverter. If the room has west sun or you are on the top floor, the 1.5 ton becomes the firm answer with no debate.
Is 1 ton AC enough for a 150 sq ft room in Dhaka?
No. 150 sq ft needs 15,000 BTU, which is above the 12,000 BTU capacity of a 1 ton. A 1 ton in a 150 sq ft Dhaka room runs continuously, never reaches the set temperature on a hot afternoon and adds roughly Tk 600 to Tk 800 a month to your bill compared with a correctly sized 1.5 ton. Buy 1.5 ton.
How many BTU per square foot do I need in Bangladesh?
For a quick rough cut, use 25 BTU per sq ft as the base figure that applies in temperate climates. For the practical load factor that Bangladeshi installers actually size to (and that you should use), use 100 BTU per sq ft. The higher figure already includes typical Dhaka and Chittagong adjustments for sun, humidity and brick-wall radiation.
Should I oversize my AC by one ton just to be safe?
No. Oversizing by one full tier short-cycles the compressor, leaves humidity in the room, raises your bill 20 to 30% and shortens the AC’s life. Right size with a 10% margin is the lowest-cost setup over five years.
What ton AC for a 1,200 sq ft Dhaka flat?
If you are cooling every room: 1.5 ton in the master, 1 ton in the second bedroom, 2 ton in the drawing room. Total around 4.5 ton across three units. If you only cool the bedrooms, drop the drawing room and the total comes down to 2.5 ton across two units.
Does ceiling height change the AC tonnage I need?
Yes. Standard ceiling height in Bangladesh is 9 ft. If your ceiling is 10 ft or more (some old colonial flats, top-floor flats with vaulted slabs), add 10% to your BTU load. A 12 ft ceiling adds 15 to 20%.
Can I install a 2 ton AC in a small bedroom and just rely on the thermostat?
Bad idea. Oversizing in a small bedroom causes short-cycling: the AC switches on, hits temperature, switches off, all within 4 to 5 minutes. The room never dehumidifies, the compressor wears out faster and your bill is higher than a correctly sized 1 ton. Match the tonnage to the room.
Window AC, split AC or portable: does the calculator change?
No. The BTU requirement of the room is the same regardless of AC format. What changes is efficiency. Portable ACs lose 20 to 25% of their rated capacity through the exhaust hose, so for a 150 sq ft room you would need a 14,000 BTU portable to match a 12,000 BTU split. Split ACs deliver their full rated BTU.
Is a 2.5 ton AC overkill for a Bangladeshi drawing room?
Depends on the size. A 1,200 sq ft flat with a 220 sq ft drawing room is fine on 2 ton. A 1,500 sq ft flat with a 280 sq ft drawing-cum-dining hall needs 2.5 ton, or two splits for zoning. Use the chart.
How much electricity does a 1.5 ton inverter AC use in Bangladesh per month?
About 9.6 kWh per day for 8 hours of use. At Dhaka’s 2026 residential tariff of Tk 7.20 per unit, that works out to roughly Tk 2,074 a month. A non-inverter 1.5 ton draws closer to Tk 2,800 a month for the same usage.
Internal Links
- AC in Bangladesh 2026 buying guide (pillar)
- Best Inverter AC in Bangladesh 2026: Top 10 Models Ranked
- 1.5 Ton AC Price in Bangladesh 2026
- AC Installation Cost in Bangladesh 2026
- Office AC Planning Guide
- Best 2 Ton AC in Bangladesh 2026
- Calculate Exact AC Tonnage: BTU Guide
Verdict
For most Bangladeshi rooms the answer comes down to one of three tonnages: 1, 1.5 or 2. Use 100 BTU per square foot of floor area as your sizing rule. Round up to the next standard ton. Add a tier if you are on the top floor or facing west sun. Buy an inverter unless your daily run hours are under four. And do not let a salesman talk you into oversizing. The bill will catch you out within a season.
Still unsure? Drop your room dimensions into the chart above and pick the matching Pickaboo collection. The model recommendations at every tier are tested against Dhaka summer conditions and refreshed each season.